WET Clean Strip (8''tool)
WET Clean Strip (8''tool), Currently the tool still working.
WET Clean Strip (8''tool), Currently the tool still working.
Used Configuration:
Tank 1: EKC
Tank 2: P1331
Tank 3 and 4: DMF
Tank 5: IPA
Known errors:
Filter from tank 4 is leaking
Heater 1 from tank 4 is broken
Heater 3 from tank 4 is broken
SP203 Mainunit: 6 Inch Bernoulli Handling; Pinlesschuck 6 Inch; Exhaust Up; 1 Medium Double Hex; 2 Medium Single Hex; Software: Major Version 117; Minor Version 2015.08.21; Gem Version GEM 5.8;
3 Chemistry Cabinetts: Cabinett 1: Maintank and Buffertank; Cabinett 2: Maintank and Buffertank; Cabinett 3:
Maintank; Chemistry Controller-Dos Wafer Size Range
Minimum: 150 mm
Maximum:150 mm
Set Size: 150 mm
Problems: Keyboard switching; voltage fluctuations; chemistry-cabinets heavily used; chemistry computer not original; modifications; FFU controller; 1 cabinet drain box repaired;
SP304 Mainunit: The system is equipped with 8-inch Bernoulli handling, Frontside and Backside (implemented by PTW) with Pinlesschuck and Pinchuck; Cold DI in Nozzle; Hot DI in Dispenser; exhaust up; heat exchangers: 1x double hex with Lauda for Di, 1x double hex with Lauda for Medium 2; 1x single hex with Lauda for Medium 1 (not used), 1x single hex with Lauda for Medium 3;
Chemistry: 2 cabinets with Maintank and Buffertank and with Mixtank with 3 Paddle wheels to fill and with Pressure regulator for the facility lines; with a Drainpumpstation.
Problems: Chemistry cabinets are used; some parts in the tool are corroded; the tool has been repaired and converted to Bernoulli handling by PTW; software adjustments have been made.
Wafer Size Range:
Minimum: 200mm
Maximun: 200mm
Set Size: 200mm
Toolcontroller with Windows XP
Remote controller
Ready for endpointdetection system
Process: Copper / Titan-Wolfram / dHF (dilluted HF)
div. spareparts possible (negotiable)